{"product_id":"dampfanlagen","title":"Steam Units","description":"\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong\u003e\u003c\/strong\u003eIBG Steam-units are used for curing epoxy or polyester resin impregnated inliners. Another field of application is the installation of PVC or PE pipes in the forming process. IBG Steam units can also be used as a hybrid system for curing with hot water.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eState of the art PLC – Software \u003cstrong\u003e(IBG steamcure 1.6) \u003c\/strong\u003econtrol system\u003c\/li\u003e\n\u003cli\u003eIndustry 4.0 life data plus documentation\u003c\/li\u003e\n\u003cli\u003eUp to 60 % less oil and energy consumption, thanks to the optimized efficiencies programming of the IBG steamcure\u003c\/li\u003e\n\u003cli\u003estainless steel piping\u003c\/li\u003e\n\u003cli\u003e10 years warranty on stainless steel pipes\u003c\/li\u003e\n\u003cli\u003e2 years warranty on the complete system\u003c\/li\u003e\n\u003cli\u003e24\/7 worldwide service support through online access by IBG technicians\u003c\/li\u003e\n\u003cli\u003eCompact design up to \u003cstrong\u003e2000 kg\/h steam\u003c\/strong\u003e for inliners up to \u003cstrong\u003eDN 2.100\u003c\/strong\u003e (84 inch)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003eTÜV tested \u0026amp; certified steam components and welding seam\u003c\/li\u003e\n\u003cli\u003eAll system components are driven by frequency converter (low energy input)\u003c\/li\u003e\n\u003cli\u003eIBG hybrid system for steam \u0026amp; boiled water\u003c\/li\u003e\n\u003cli\u003eMore than 220 steam units worldwide delivered.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0650\/7855\/8951\/files\/Resim1_480x480.jpg?v=1695201787\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0650\/7855\/8951\/files\/Resim1_480x480.jpg?v=1695201787\"\u003e \u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0650\/7855\/8951\/files\/Resim2_480x480.jpg?v=1695201804\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0650\/7855\/8951\/files\/Resim2_480x480.jpg?v=1695201804\"\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eIBG steam units can be used for the rehabilitation of DN 50 – 2.000 mm \/ 2” to 80”\u003c\/p\u003e\n\u003cp\u003epipes and are made entirely of components with steam certification. They are according to customer requirement and challenges on the construction site. The models are therefore available in different sizes and designs.\u003c\/p\u003e\n\u003ch2\u003eTechnical Standard\u003c\/h2\u003e\n\u003cp\u003eState of the art PLC – Software \u003cstrong\u003e(IBG Steamcure 1.6) \u003c\/strong\u003econtrol system Incl. SIEMENS SPS-7 hardware and internet access\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustry 4.0\u003c\/strong\u003e life data plus documentation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTwo years warranty\u003c\/strong\u003e on the complete system\u003c\/li\u003e\n\u003cli\u003eCompact design up to \u003cstrong\u003e1200 kg\/h steam\u003c\/strong\u003e ( BTU) for inliners up to \u003cstrong data-mce-fragment=\"1\"\u003eDN 2.100\u003c\/strong\u003e (84 inch)\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTÜV tested\u003c\/strong\u003e \u0026amp; certified steam components and welding seam\u003c\/li\u003e\n\u003cli\u003eFeedwater tank with energy recovery\u003c\/li\u003e\n\u003cli\u003eWater treatment with double unit, for continuous operation …\u003c\/li\u003e\n\u003cli\u003eOil- and water tanks. Size according to customer requirements\u003c\/li\u003e\n\u003cli\u003eSensors for pressure; temperature; laminate temp.; water \u0026amp; oil consumption; water and fuel level.\u003c\/li\u003e\n\u003cli\u003eStainless steel piping and safety valve with guided media outlet\u003c\/li\u003e\n\u003cli\u003eB-Station incl. trolly. B station with control valve; PLC control; radio connection to A station; battery with charger and exhaust system. Extremely quite due to patented exhaust muffler. Condensate line with 3 mtr. hose. Warning light (flasher).\u003c\/li\u003e\n\u003cli\u003eWireless remote control with emergency stop\u003c\/li\u003e\n\u003cli\u003eSet of lances and steam hoses (3 x 5 mtr) with coupling\u003c\/li\u003e\n\u003cli\u003eStandard version suitable for operating temperature up to 130 °C (266 °F).\u003c\/li\u003e\n\u003cli\u003eInternal\/external lighting\u003cbr\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eOptional\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eInversion unit for additional steam hose (DN 80) into the inliner.This allows faster and more even heating of the inliner laminate\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003eRadio remote control and camera monitoring\u003c\/li\u003e\n\u003cli\u003eWireless remote control with emergency stop\u003c\/li\u003e\n\u003cli\u003eChiller unit for controlled cool down sequence\u003c\/li\u003e\n\u003cli\u003eAdd-on system for second Blower with electronic switch box\u003c\/li\u003e\n\u003cli\u003eIBG hybrid system for steam \u0026amp; boiled water\u003c\/li\u003e\n\u003cli\u003eIntegration of additional temperature sensors (laminate) over the entire inliner length Version\u003c\/li\u003e\n\u003cli\u003eVersion up to 180°C (356°F) operating temperature\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eTechnical Data\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e Notice:\u003c\/strong\u003e \u003cstrong\u003e1 bar\u003c\/strong\u003e = 14,5 psi       \u003cstrong\u003e1 kg steam\u003c\/strong\u003e = 2.418 BTU\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd width=\"75\"\u003e\n\u003cp\u003e\u003cstrong\u003eTYPE\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKg steam\/h\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"84\"\u003e\n\u003cp\u003e\u003cstrong\u003eMax DN\u003cbr\u003e Inliner\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIn inch-mm\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"84\"\u003e\n\u003cp\u003e\u003cstrong\u003eStandard\u003cbr\u003emax curing pressure\u003cbr\u003e bar\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"84\"\u003e\n\u003cp\u003e\u003cstrong\u003ePower Cons.\u003cbr\u003e 400 V\/\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIn KW incl. 1 or 2 Blower\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"84\"\u003e\n\u003cp\u003e\u003cstrong\u003eOil Cons. \u003cu\u003eaverage\u003c\/u\u003e per hour in ltr.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e \u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"64\"\u003e\n\u003cp\u003e\u003cstrong\u003ePLC control and remote control\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"83\"\u003e\n\u003cp\u003e\u003cstrong\u003eSt.Steel piping + steam certified components\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"54\"\u003e\n\u003cp\u003e\u003cstrong\u003eIndustry 4.0 standard with life data\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"68\"\u003e\n\u003cp\u003e\u003cstrong\u003eB-Station with\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e400 mtr.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ewireless connection\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"75\"\u003e\n\u003cp\u003e\u003cstrong\u003e400\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"84\"\u003e\n\u003cp\u003e20 - 500\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"84\"\u003e\n\u003cp\u003e1,25\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"84\"\u003e\n\u003cp\u003e20\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"84\"\u003e\n\u003cp\u003e\u003cstrong\u003e20 \u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"64\"\u003e✅\u003c\/td\u003e\n\u003ctd width=\"83\"\u003e✅\u003c\/td\u003e\n\u003ctd width=\"54\"\u003e✅\u003c\/td\u003e\n\u003ctd width=\"68\"\u003e✅\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"75\"\u003e\n\u003cp\u003e\u003cstrong\u003e800\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"84\"\u003e\n\u003cp\u003e32 – 800\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"84\"\u003e\n\u003cp\u003e1,0\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"84\"\u003e\n\u003cp\u003e25\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"84\"\u003e\n\u003cp\u003e\u003cstrong\u003e35 - 45 \u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"64\"\u003e✅\u003c\/td\u003e\n\u003ctd width=\"83\"\u003e✅\u003c\/td\u003e\n\u003ctd width=\"54\"\u003e✅\u003c\/td\u003e\n\u003ctd width=\"68\"\u003e✅\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"75\"\u003e\n\u003cp\u003e\u003cstrong\u003e1.200\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"84\"\u003e\n\u003cp\u003e40 – 1.000\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"84\"\u003e\n\u003cp\u003e1,0\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"84\"\u003e\n\u003cp\u003e30\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"84\"\u003e\n\u003cp\u003e\u003cstrong\u003e50 - 60 \u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"64\"\u003e✅\u003c\/td\u003e\n\u003ctd width=\"83\"\u003e✅\u003c\/td\u003e\n\u003ctd width=\"54\"\u003e✅\u003c\/td\u003e\n\u003ctd width=\"68\"\u003e✅\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"75\"\u003e\n\u003cp\u003e\u003cstrong\u003e1.600\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"84\"\u003e\n\u003cp\u003e56 – 1.400\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"84\"\u003e\n\u003cp\u003e1,0\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"84\"\u003e\n\u003cp\u003e45\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"84\"\u003e\n\u003cp\u003e\u003cstrong\u003e70 - 80 \u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"64\"\u003e✅\u003c\/td\u003e\n\u003ctd width=\"83\"\u003e✅\u003c\/td\u003e\n\u003ctd width=\"54\"\u003e✅\u003c\/td\u003e\n\u003ctd width=\"68\"\u003e✅\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"75\"\u003e\n\u003cp\u003e\u003cstrong\u003e2 x 1.000\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"84\"\u003e\n\u003cp\u003e84 – 2.100\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"84\"\u003e\n\u003cp\u003e1,0\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"84\"\u003e\n\u003cp\u003e\u003cstrong\u003e55\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"84\"\u003e\n\u003cp\u003e\u003cstrong\u003e95 - 105\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"64\"\u003e✅\u003c\/td\u003e\n\u003ctd width=\"83\"\u003e✅\u003c\/td\u003e\n\u003ctd width=\"54\"\u003e✅\u003c\/td\u003e\n\u003ctd width=\"68\"\u003e✅\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0650\/7855\/8951\/files\/zzz_480x480.png?v=1695204246\" alt=\"\"\u003eIBG INV Drum 2.200 – DN 1.200 in sea container 20 ft, with Swivel system device +-90 for the INV drum, plus steam unit 1.000 kg\/h.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003e Software: IBG Steamcure\u003csup data-mce-fragment=\"1\"\u003e®\u003c\/sup\u003e 1.6 \u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0650\/7855\/8951\/files\/g1_480x480.jpg?v=1695202502\" width=\"100%\"\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0650\/7855\/8951\/files\/g2_480x480.jpg?v=1695202513\" width=\"100%\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThe software IBG steamcure® 1.6, is used for reliable installation and documentation of inliner in pipe system. The software enables the control of the optimal energy input as well as the automatic regulation of the curing parameters. This permanent calculation of the optimal parameters regarding steam quantity; air quantity; volume flow rate; temperature and pressure would not be possible with a manual operation and an energy input reduction of up to 60% would be unachievable. Due to the Industry 4.0 standard, a permanent documentation of the process parameters (if requested via Internet connection with real-time data transmission) is carried out, which forms a determining basis regarding the QA standards. This is the basis for reproducible construction site quality. Also of high importance is the wireless connection of the B-Station (incl. battery pack), which allows a continuous control of the outlet valves (pressure and temperature) without additional personnel on site. The software is available in all common languages and technical units (of measure).\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cimg width=\"100%\" alt=\"IBG Steam Unit Pictures 1\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0650\/7855\/8951\/files\/p1_480x480.jpg\"\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cimg alt=\"IBG Steam Unit Pictures 2\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0650\/7855\/8951\/files\/p2_480x480.jpg?v=1695202921\" width=\"100%\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eTraining: IBG steamcure® 1.6 \u0026amp; Steam-units\u003c\/h2\u003e\n\u003cp\u003eBG offers basic training for all systems at our training center in Alzenau. In addition, all system operators are accompanied and trained by IBG technicians on a construction site assignment. This makes it possible to avoid initial application problems and creates confidence among the employees. Also in the further course of application, our technicians are available for problem solutions via internet access at any time. This avoids considerable travel costs and the response time is extremely short. The \"plug\u0026amp;play\" system design of IBG HydroTech also has a positive influence on this, enabling the user to easily replace components on site in the event of damage. Supplementary training courses can also be requested from our service office at any time.\u003c\/p\u003e\n\u003ch2\u003e\u003c\/h2\u003e\n\u003ch2\u003e3D Project View\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ciframe width=\"426\" height=\"240\" src=\"https:\/\/my.matterport.com\/show\/?m=YKz5jRnJS4L\" frameborder=\"0\" allowfullscreen=\"\" allow=\"xr-spatial-tracking\"\u003e\u003c\/iframe\u003e","brand":"IBG HydroTech GmbH","offers":[{"title":"Default Title","offer_id":46946846703956,"sku":null,"price":450000.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0650\/7855\/8951\/files\/steam-unit-ibg-hydro-tech-1.jpg?v=1695221363","url":"https:\/\/nozzle24.com\/en-pl\/products\/steam-unit","provider":"Nozzle24","version":"1.0","type":"link"}